C4000I
44
532100 - Rev.A
Tr
ansla
tion of the original instruc
tions
ENGLISH
12.5 ERRORS
Errors are malfunctions that prevent the automation
system from working. They are indicated by the steady
ERROR LED (
DL6
) on the board.
If there is an error, remove the cause of it in order to
resume normal operation.
To check any active errors, press the + and - buttons
simultaneously while the display shows the automated
system status.
Er
appears on the display followed by
a numerical code:
Errors
Intervention required
01
Board failure
Replace the board
05
Set-up incorrect
Repeat the set-up procedure
08
BUS 2easy Error
Make sure that there are not two
pairs of devices with the same
address.
09
B U S 2 e a s y o u t p u t
short-circuited
Check the connections of the
BUS 2easy devices that are con-
nected and registered.
12
Call BUS 2easy
Check the operation of the BUS
devices. Repeat the acquisition
procedure if necessary
13
FAIL SAFE
Check that the safety devices (edg-
es) are working correctly.
14
Configuration error
Check the board configuration
(opening direction..). Repeat the
set-up procedure if necessary
15
Movement time-out
Check the value of parameter t in
advanced programming
17
Motor encoder failure
Check the connections, the encoder
power LED or replace the motor
encoder
12.6 CHECK FIRMWARE VERSION
When the display of the E4000I is switched on, it shows
the following in succession:
-
bo
(Bootloader)
-
firmware version (2 digits separated by a point)
-
automation system status