22
23
24
C4000I
27
532100 - Rev.A
2 3 4 5 6 7 8 9
1
OPEN A
OPEN B
SAFE OP
SAFE CL
GND
+24
+24
ST
OP
CL
OSE
24V
1A max
MOT1
MOT1
M
J15
J14
Tr
ansla
tion of the original instruc
tions
ENGLISH
blue
brown
6.2 CONNECTIONS
F
Always switch off the electricity supply before making
connections.
For the Master-Slave configuration, please see the
specific section.
BOARD-POWER SUPPLY CABLE
The cable is connected at the factory between connectors
J19 of the board and J4 of the power supply.
MOTOR
1. Route the motor cable through one of the cable
glands at the base of the enclosure.
2. Connect the cable to terminal board J4 following the
colour scheme of the cables (
22
).
ENCODER
Connect the encoder cable to connectors J14 and J15 of
the board (
23
). Use the cable gland provided.
The encoder must always be connected in order for the
automation system to operate.
BUS DEVICES
If no BUS 2easy devices are used, leave the BUS 2easy
terminal board free.
For connecting and assigning addresses see
38
.
CONTROL DEVICES
1. Route the control devices cable through one of the
cable glands at the base of the enclosure. If necessary,
use one of those on the cover of the enclosure.
2. Connect the devices to terminal board J6 of the
board (
24
).
Multiple NO contacts on same input must be connect-
ed in parallel. Multiple NC contacts on same input
must be connected in series.
TERMINAL BOARD J6:
1
OPEN A
N O co nt a c t, co n n e c t a p u s h - b u t -
ton or another type of pulse gener-
ator which, by closing a contact, com-
mands the TOTAL OPENING of the gate.
2
OPEN B
NO contact, connect a push-button or another
type of pulse generator which, by closing a
contact, commands the PARTIAL OPENING
of the gate
If the Hr function (advanced
functions) is enabled, it com-
mands the FORCED OPENING of
the automation with a main-
tained command.