32
C4000I
41
532100 - Rev.A
2 3 4 5 6 7 8 9
1
OPEN A
OPEN B
SAFE OP
SAFE CL
GND
+24
+24
ST
OP
CL
OSE
BUS
BUS
2 3 4 5 6 7 8 9
1
OPEN A
OPEN B
SAFE OP
SAFE CL
GND
+24
+24
ST
OP
CL
OSE
BUS
BUS
1
2
1
2
Tr
ansla
tion of the original instruc
tions
ENGLISH
10. MASTER-SLAVE
The
Master
-
Slave
configuration makes it possible to
install two opposite opening leaves with synchronous
movement.
When programming, one gearmotor must be defined
as
Master
and the other as
Slave
. The
Master
gearmo-
tor manages all the controls and movements.
The control devices must be connected to the
Master
gearmotor.
The functioning logic must only be programmed on
the
Master
board. The anti-crushing function is
active on each gearmotor and commands the reverse
of both.
CONNECTION
1. Connect the gearmotors to the BUS 2easy polar-
ised connection
32
).
2. Connect the devices (see
2 7
). The inputs
for the command devices are disabled on the
Slave
board.
Connections
Master
Slave
Power supply
Motor
Encoder
Control devices
Outputs
Flashing light
3. The BUS 2easy devices can be connected to the
Master
or to the
Slave
board. The devices must be
registered on the
Master
gearmotor.
SLAVE
GEARMOTOR CONFIGURATION
1. Switch on the
Slave
gearmotor. The board turns
on. The display reads in sequence:
-
firmware version (2 digits separated by a point)
-
LO
flashing if set-up is required, or the automated
system status
2. Access the Basic programming and set:
-
Ct
=
SL
for configuring the board as
Slave.
-
dl
according to the opening direction of the leaf
3. Check the status of the LEDs on the board:
LED DL7 (Red)
Master
-
Slave
synchronisation absent or the line
is short circuited.
LED DL3 (Green)
Master
-
Slave
synchronisation present.
4. Release the gearmotor
5. Set up the
Slave
gearmotor (see
33
).
6. Start up (see
29
).