![background image](http://html1.mh-extra.com/html/faac/c4000i/c4000i_original-instructions-manual_3190522029.webp)
C4000I
29
532100 - Rev.A
Tr
ansla
tion of the original instruc
tions
ENGLISH
7. START-UP
RISKS
PERSONAL PROTECTIVE EQUIPMENT
!
During operation there is a risk of fingers and hands
being trapped between the rack, pinion and cover.
If two gearmotors are installed in the following
configuration
Master
-
Slave
, before starting up of the
Master,
it is necessary to have configured the
Slave
gearmotor (see the specific section).
3. Power up the system (gearmotor
Master
). The
board turns on. The display reads in sequence:
-
bo
(Bootloader)
-
firmware version (2 digits separated by a point)
-
LO
flashing if set-up is required, or the automated
system status
4. Check the status of the LEDs at in standby (see
§ 12.1)
The BUS 2easy LEDs must be checked after the devices
have been registered.
5. Memorise the radio controls present in the system
(§ 9.3).
6. Program the E4000I.
!
Always set the opening direction (
dl
Basic Pro-
gramming):
7. Register the BUS 2easy devices, if installed (§ 9.4).
8. Carry out the setup procedure (§ 7.3).
9. If the XBAT 24 battery is being used:
-
Cut off the plant's power supply
-
Connect the XBAT 24 battery
-
Switch on power to the system.
10. Once the functional tests have been completed, it
is recommended to save the settings (§ 11).
7.1 PROGRAMMING
BASIC PROGRAMMING
List of basic functions:
8
1. Press and hold down
F
until the first basic
function appears. (Each function is displayed
as long as
F
remains pressed).
F
2. Release: the value of the function appears
(default or programmed).
F
3. Use the
+
or
-
button to modify the value.
-
+
4. Press
F
to confirm the value displayed. Go
to the next function. The modified value
becomes effective immediately.
F
Proceed in the same way for all the functions. The last function
(
St
) allows you to close the program.
5. In
St
select
Y
or
no
using the
+
+
/
-
buttons:
Y
= save the new program
no
= DO NOT save the new program
6. Press
F
to confirm and close the program. It returns to the
automation status view.
ADVANCED PROGRAMMING
List of advanced functions:
9
1. Press and hold down
F
and then
+
as well,
until the first advanced function appears. (Each
function is displayed as long as
F
remains
pressed).
F
+
+
2. Release: the value of the function appears
(default or programmed).
F
+
+
3. Use the
+
or
-
button to modify the value.
-
+
4. Press
F
to confirm the value displayed. Go
to the next function. The modified value
becomes effective immediately.
F
Proceed in the same way for all the functions. The last function
(
St
) allows you to close the program.
5. In
St
select
Y
or
no
using the
+
+
/
-
buttons:
Y
= save the new program
no
= DO NOT save the new program