Assigning an address to the photocells.
1 0 0 0
CL FSW
1 0 0 1
1 0 1 0
1 0 1 1
1 1 0 0
1 1 1 0
0 0 0 0
OP FSW
0 0 0 1
0 0 1 0
0 0 1 1
0 1 1 1
0 1 0 0
OP/CL FSW
0 1 0 1
1 1 1 1
OPEN
Assign an address to each pair of photocells by setting
the four DIP switches (DS1) on the transmitter and the
corresponding receiver.
The transmitter and receiver of a pair of photocells
must have the same DIP switch settings.
There must never be two or more pairs of photocells
with the same DIP switch settings. If there is more
than one pair of photocells with the same address, a
conflict error is generated.
2. Register the BUS 2easy photocells (
bu
Basic pro-
gramming).
3. Check the status of LEDs DL3 and DL7 (
).
4. Check that the photocells are operating correct-
ly. When the gate is moving, interrupt the beam
ON
1 2 3 4
9.4 BUS 2EASY DEVICES
This board has a BUS 2easy circuit for connecting
BUS 2easy devices (photocells, wireless safety edge
system, control devices).
If no BUS 2easy accessories are used, leave the
BUS 2easy connector free. Do not bridge.
CONNECTION
1. Route the cable of the BUS 2easy devices through
one of the cable glands at the base of the enclo-
sure. If necessary, use one of those on the board
enclosure cover.
2. Connect any BUS 2easy devices (photocells, wire-
less safety edge system and controls) to terminal
board J10.
The BUS line does not require a matching polarity
connection.
!
The overall length of the BUS 2easy cables must not
exceed 100 m.
BUS 2EASY PHOTOCELLS
Type of use:
Closing pho-
tocells
Ac tive during
closing
When an obstacle is detect-
ed, they stop the gate and
reopen it.
Opening pho-
tocells
Ac tive during
opening
When an obstacle is detected,
they stop the gate and close it.
Opening/clos-
ing photocells
Ac tive during
both opening
and closing
When an obstacle is detected,
they stop the gate and reverse
its direction of movement.
P h o t o c e l l s
used as pulse
generators
Always active
When an obstacle is detected,
they send an OPEN A com-
mand.
Select the reverse type: immediate or reversing on
disengagement (functions
Ph
and
oP
Advanced
programming).
1. Assign an address to the BUS 2easy photocells.