background image

 

WENSHING Electronics Co., Ltd.

 

           

           

 

 

   

  RD-747 Instruction Manual 

V1.03 

page 1     

 

 

 

Active RFID Garage Door 

Control System 

(Home Use)

 

 

Instruction Manual

 

                                                       

 

 

                                                                 

Model: RD-747 

 
 
 
 
 
 
 
 
 
 
 
 

 
 

Instruction Manual Revision History 

Version 

Date 

Changes 

V1.02 

Jan. 16, 2009 

First Edition 

V1.02 

May. 05, 2009 

Second Edition 

V1.03 

Jul. 15, 2009 

First Edition 

Summary of Contents for RD-747

Page 1: ...nual V1 03 page 1 Active RFID Garage Door Control System Home Use Instruction Manual Model RD 747 Instruction Manual Revision History Version Date Changes V1 02 Jan 16 2009 First Edition V1 02 May 05 2009 Second Edition V1 03 Jul 15 2009 First Edition ...

Page 2: ...ring Diagram 7 RD 747 Elevator 1F B1 8 RD 747 Elevator 1F B1 B2 9 RD 747 Elevator 1F B1 B2 B3 10 Every part of TX 800 Description 11 RD 747 Switch Function Description 11 RD 747 Install Steps 12 RD 747 Voltage Required 12 TX 800 Boot Tips 12 RD 747 TX 800 Pairing Setting Normal Mode 12 RD 747 TX 800 Paring Setting Automatically Open 13 TX 800 Automatically open conditions 14 Copy TX 800 14 Conditi...

Page 3: ...atement recorded by the note When consumers in contravention of this statement recorded note of the operation I am afraid our company could not shoulder any responsibility Products are defective the Company will be responsible for free to amend the flaws or to the same flawless product or its equivalent products in exchange However the Company does not assume based on the requirements of the flaw ...

Page 4: ...ps of relays 12A 250Vac also provide diversify using ways switch design is a user friendly functional to let you set the mode you required It also provides an integrated line link so that it can significantly decrease lower error rate and difficulty of construction Wide application such as difference types of rolling door elevators lighting control products are applicable Feature When you get in o...

Page 5: ...y 110 dBm Packet error rate is 1 Action Temperature 20 C 80 C Storage Temperature 20 C 90 C Dimension 153 87 5 64 mm Weight 243 4 g TX 800 Wireless Remote Control Power CR 2032 Frequency 925 928MHz Output Power 10mW Transmission Distance Open space 100m Sensitivity 110 dBm Packet error rate is 1 Action Temperature 20 C 60 C Storage Temperature 20 C 45 C Relative Humidity 60 Dimension 66 33 5 12 3 ...

Page 6: ...anual V1 03 page 6 Every Part of RD 747 Description Surface location No Name Description 1 Function set key Link with remote control 2 Switch Use switch to adjust the mode you required 3 Integrated connector Voltage and signal input and output 3 2 1 ...

Page 7: ...nge Line Gray Line Light Brown Line 2F Black Line UP Up White Line DOWN Down Yellow Line COM NC Stop Green Line STOP Stop Blue Line 2F Black Line Light Brown Line AC Orange Line AC Purple Line Gray Line Up COM N O N C COM NO NC COM N O NC AC 110V 240V RF Two way Transceiver DPA Switch White Line JUMP KE Y Brown Line Down Stop Blue Line Purple Line Green Line Orange Line Gray Line UP Up White Paral...

Page 8: ...P COM N O NC AC 110V 240V KE Y White Line Ground 1F Yellow Line Underground 1F Red Line COM Point Green Line Ground 2F Blue Line COM Point Purple Line AC 110 220V Orange Line AC 110 220V Gray Line Flare Brown Line Flare Black Line Underground 2F White Line Red Line Blue Line RF Two way Transceiver DPA Switch Black Line Brown Line Gray Line JUMP Green Line Orange Line Purple Line ...

Page 9: ...C STOP COM N O NC AC 110V 240V KE Y RF Two way Transceiver DPA Switch White Line Red Line Blue Line Black Line JUMP Green Line Purple Line Orange Line Brown Line Gray Line White Line Ground 1F Yellow Line Underground 1F Red Line COM Point Green Line Ground 2F Blue Line COM Point Purple Line AC 110 220V Orange Line AC 110 220V Gray Line Flare Brown Line Flare Black Line Underground 2F ...

Page 10: ... Purple Line AC 110 220V Orange Line AC 110 220V Gray Line Flare Brown Line Flare Black Line Underground 3F AC IN Red line and blue line in parallel connection Red line and blue line in parallel connection 1F UP B1 B2 B3 B3 COM NO N C 1F UP COM N O N C B1 COM NO NC B2 COM N O NC AC 110V 240V KE Y White Line Red Line Blue Line RF Two way Transceiver DPA Switch Black Line Brown Line Gray Line JUMP G...

Page 11: ... is 15mins When time is 15mins it will be off automatically In the meanwhile it will automatically open for 15mins and followed by this cycle RD 747 Switch Function Description Function Operation Switch 1 Switch 2 Switch 3 Switch 4 1 Open Close by hand OFF OFF OFF OFF 2 TX 800 automatically opens when you hold TX 800 and near door OFF ON OFF OFF Switch Diagram Key1 Key2 Key3 Key4 Function 1 Functi...

Page 12: ...it boot you heard three sounds from buzzer and it will has a record of three hosts inside TX 800 When it boot you heard four sounds from buzzer and it will has no record of host inside TX 800 RD 747 TX 800 Pairing Setting Normal Mode Before RD 747 electricity host need to adjust the switch according to the function you required After host power settings finished press function key around 2 3 secon...

Page 13: ...paring list and it is still failure for 10 seconds it will has a long sound from TX 800 and leave 6 If TX 800 pair RD 747 successful it will has two long sounds and then leave RD 747 TX 800 Paring Setting Automatically Open Before electricity host need to adjust the switch side according the function you required After host power settings finished press function key around 2 3 seconds to enter pai...

Page 14: ...o long sounds and then leave 7 After finished paring please take TX 800 to the auto door when you arrival the assigned place the door will be open automatically after 4 seconds Suggest you to expend memory location of door which you hope to open and press the key1 When you heard two long sounds from TX 800 it is meaning finished setting and please press key3 to leave setting mode TX 800 Automatica...

Page 15: ...ll heard B has seven sounds If there are not two long sound from A please repeat step1 5 If you heard four sounds from A it is meaning service ID is different Condition for Paring and Copy Each Other This product had been finished service ID setting for every customer TX 800 includes service ID it can copy from the same service ID or TX 800 without service ID It also can paring with RD 747 which h...

Page 16: ...us wireless restriction and way of interfering with the characteristic FCC Consistent Declaration U S A Only Attention FCC rule regulation modified and changed must allowed by WENSHING Electronics company otherwise that would make you operate this apparatus invalid This apparatus adopted test according to chapter 15 that FCC regulation accord with Class B digital restrictions of device These limit...