RFC 2544 Test Setup and Results
NetBlazer
81
Subtests Configuration
Throughput Configuration
The objective of this test is to find the throughput of the device under test
for which there is no frame loss. Starting at the specified maximum rate
(
Max. Rate
), the rate converges towards the highest throughput without
frame loss with the test having a predefined duration (
Test Time
). The
search is done with a halving/doubling method until a final value is
reached. The throughput measurement is validated the number of times
specified (
Nb. of Validations
). The
Accuracy
settings specify how precise
that result must be. The test is performed for each defined frame size.
Note:
Throughput
must be enabled from
Test Time (MM:SS)
: Enter the Test Time value in seconds. Possible
values are
1
second to
30
minutes. The default setting is
1
second
(
00:01
).
Accuracy
: Enter the
Accuracy
value as a percentage of the line rate
(
%
),
Mbit/s
, or in
Gbit/s
. The accuracy is not based on the configured
Maximum Rate
but on the Ethernet line rate. The accepted values are
as follows:
Accuracy
Interface Speed
10 Mbit/s
100 Mbit/s
1000 Mbit/s
10G LAN
10G WAN
%
Default:
0.1 - 10.0,
1.0
Mbit/s
Default:
0.01 - 1.00
0.10
0.1 - 10.0
1.0
1 - 100
10
10 - 1000
100
Gbit/s
Default:
Not Applicable
Not Applicable
0.001 - 0.100
0.010
0.01 - 1.00
0.10
Summary of Contents for FTB-860
Page 7: ...NetBlazer vii B Glossary 371 Acronym List 371 VLAN 379 1588 PTP 380 SyncE 385...
Page 12: ......
Page 16: ......
Page 20: ......
Page 30: ......
Page 84: ......
Page 110: ......
Page 122: ......
Page 152: ......
Page 166: ......
Page 182: ......
Page 192: ......
Page 224: ......
Page 366: ......
Page 376: ......
Page 382: ...Specifications 370 FTB 860 880 Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s...