O
CTOBER
2002
E
XABYTE
VXA-2 A
UTO
P
AK1x7
A
UTOLOADER
91
S
AFETY
AND
R
EGULATORY
A
GENCY
C
OMPLIANCE
E
LECTROSTATIC
D
ISCHARGE
(ESD) I
MMUNITY
The autoloader complies with EN 61000-4-2:1995, Electromagnetic
Compatibility (EMC), Part 4: Testing and Measurement Techniques, Part 2:
Electrostatic Discharge (ESD) Immunity.
Exabyte has extended testing as follows:
!
Up to 12,000 volts air discharge applied to all non-metallic surfaces
!
Up to 8,000 volts direct discharge applied to all metallic/conductive surfaces
In each case, there is no degradation or non-recoverable loss of function due to
damage of equipment or firmware.
R
ADIATED
R
ADIO
F
REQUENCY
F
IELD
I
MMUNITY
The autoloader complies with EN 61000-4-3:1996 and ENV 50204:1995,
Electromagnetic Compatibility (EMC), Part 4: Testing and Measurement
Techniques, Part 3: Radiated Radio-Frequency Immunity.
The autoloader will continue to operate without error while being exposed to
an electromagnetic field of 3V/m.
E
LECTRICAL
F
AST
T
RANSIENT
(EFT)/B
URST
I
MMUNITY
The autoloader complies with EN 61000-4-4:1995, Electromagnetic
Compatibility (EMC), Part 4: Testing and Measurement Techniques, Part 4:
Electrical Fast Transient/Burst Immunity.
The autoloader will continue to operate without error when exposed to EFT of
±1,000 V on the AC power ports and ±500 V on the I/O ports (SCSI connectors
and serial port).
S
URGE
I
MMUNITY
The autoloader complies with EN 61000-4-5:1995, Electromagnetic
Compatibility (EMC), Part 5: Surge Immunity.
The autoloader will continue to operate without error after being subjected to