O
CTOBER
2002
E
XABYTE
VXA-2 A
UTO
P
AK1x7
A
UTOLOADER
71
E
RROR
C
ODES
198
CHM full before move
. There
was a cartridge in the robot
before a move operation,
initialize element status, or
diagnostic test.
!
Remove the magazine and look for anything that might be
obstructing the robot.
!
Make sure the autoloader is not being used by any host,
then reset the autoloader from the operator panel. If
necessary, power the autoloader off and back on to reset
the tape drive.
!
If the error persists, contact your service provider. You may
be asked to supply a diagnostic listing, and you may need
new firmware.
199
Remove tape in drive
. The
cartridge must be removed
before the autoloader can begin
its POST.
Remove the cartridge from the tape drive.
210
Remove all tapes for calib
. All
cartridges must be removed so
the autoloader can begin
calibration.
!
Remove the magazine (it is unlocked).
!
Remove cartridges from all the magazine slots, the tape
drive, and the picker.
!
Replace the magazine. The autoloader will automatically
calibrate.
211
Eject sensor error.
There is a
bad sensor or the autoloader
cannot communicate with the
tape drive over the serial
interface and there is a cartridge
protruding from the tape drive.
!
Make sure the autoloader is not being used by any host,
then reset the autoloader and the tape drive by powering
the autoloader off and back on to reset the tape drive.
!
If the error persists, contact your service provider.
212
Remove tape in robot.
A
cartridge was in the robot during
POST.
!
Remove the magazine (it is unlocked).
!
Remove the cartridge from the robot and place it in the
magazine (if you know where it goes).
!
Replace the magazine. The autoloader automatically
resumes post.
Table 6-1
Autoloader error codes (continued)
Code
Description
Corrective action