To upgrade the autoloader’s firmware using the Console interface:
1.
1.
1.
1.
Obtain new firmware for the autoloader. You can download new firmware
from Exabyte’s web site (www.exabyte.com), or you can contact Exabyte
Technical Support.
2.
2.
2.
2.
Access Console by following the steps on
3.
3.
3.
3.
If desired, you can use the SCSI READ BUFFER command to copy the
current firmware to disk. To do this, use a software application that can issue
SCSI commands. For more information about the SCSI commands, refer to
the SCSI reference for your autoloader.
4.
4.
4.
4.
From Console, type
flash
and press
Enter
. This displays the Flash screen,
as shown in
Caution
Do not upgrade firmware unless Exabyte Technical Support has advised you to do
so. If performed improperly, the upgrade procedure can render your autoloader
inoperable. Consult with Exabyte Technical Support before performing an
upgrade.
Because of memory limitations, the autoloader cannot validate the new firmware
data before erasing and reprogramming the flash EEPROM. If the checksum
calculated by the autoloader does not match the embedded checksum, the new
firmware will be unusable. Therefore,
before
performing the write firmware
operation, use the READ BUFFER SCSI command to create a copy of your current
firmware.
Figure 5-3
Console Flash screen