Instruction Manual MM850432 ed. 05c
48
In
Thermocouple
RTD thermometer
Current
Voltage
Resistance
Press < > to SET
•
Press the [ ] and [ ] keys to highlight the “
Process Function
” parameter.
•
Press the [ ] key to select the option. Press the [
ESC
] key to return in measure mode without changes.
Process Function
XScale
LinMan [ ]
Press < > to SET
•
Press the [ ] and [ ] keys to highlight the type of Mathematic functions you have to use.
XScale
: allows to perform a linear or square scaling for your input parameter (e.g. For transforming a 4/20 mA input to a –1 to 2 bar reading on the display)
LinMan
: you can transfer from PC (using the optional LinMan PC software) special linearization sensor tables (e.g. The RTD calibration ohm vs. °C table or the
polynomial coefficients). Please refer to LinMan software paragraph for the complete procedure.
•
Press the [ ] key to select the option. Press the [
ESC
] key to return in measure mode without changes.
If you have select “
XScale
” option, the display will show:
Xscale
X1
X2
X3
X4
Set X1
Press < > to SET
•
Press the [ ] and [ ] keys to choose the Xscale function.
•
Press the [ ] key to confirm the selection and go to measuring mode. Press the
If you have select “
LinMan
” option, the display will show the list of all sensor
linearizations you have created using the optional PC software LinMan.
LinMan
My Sensor 1
My Sensor 2
My Sensor 3
My Sensor 4
My Sensor 5
Press < > to SET
•
Press the [ ] and [ ] keys to choose the sensor name.