INSTALLATION - DOOR CONFIGURATION
42
Installation guide
Advanced functions
Door syn-
chronisa-
tion
Select door
M1
To select the operator (M1 or S1) to be displayed in the
digital selector.
S1
Doors Synchronism
Enable:
1- enabled;
2- disabled
(default
value)
To enable or disable synchronism between Master and
Slave.
Synchronism dis-
tance (0 to 45º de-
fault value:
0
)
For double swing doors. Increasing the value increases the
delay in starting the Slave operator's movement relative to
starting the Master operator's movement.
Interlock
Use KI/KA
inputs ONLY for
interlocking
Enable /
Disable
To enable or disable the interlock.
Type of interlock:
-
Normal Interlock
(default value)
- Smart Interlock
N
ORMAL
INTERLOCK
: the master operator (2) does not open
(even if the interior or exterior activation device is enabled)
until the master operator (1) has completed the closing
movement.
S
MART
INTERLOCK
: when the exterior activation device is
enabled, the master operator (2) does not open until it (1)
is in closed position. The Master operator (2) opens when
the interior activation device is enabled, even if the Master
(1) has not completed the closing movement.
Interlock time (0 to
300 sec, default
value:
0
)
Enable or disable interlock between Master operators (M1
and M2).
Interlock release system: the interlock system is
automatically released if the Master operator (1) does not
close after a preset time.