INSTALLATION - DOOR CONFIGURATION
46
Installation guide
I n p u t s /
Outputs
(cont.)
Inputs
(1,2,3,4)
(cont.)
Mode
(cont.)
Disabled Mode
(de-
fault value)
Input not configured (by default).
Activa-
tion
NO
(default value)
Normally Open Input Signal.
NC
Normally Closed Input Signal.
Outputs
(1,2)
Mode
Ding-Dong Mode
The operator sends a specific signal in each start of
opening movement.
Door Open Mode
The operator sends a continuous signal when the door is
in open position.
Anti-Tamper
Mode
The operator sends a continuous signal if tampering is
detected in a closed door.
The "Keep door closed" parameter must be
enabled.
Door Closed
Mode
The operator sends a signal when the door is in closed
position.
Warning Mode
The operator sends a signal whenever a warning is
detected (e.g. Warning 20, etc.).
Toilet engaged
Specific output for "accessible toilets".
Toilet free
Specific output for "accessible toilets".
Disabled Mode
(de-
fault value)
Output not configured (default).
Activa-
tion
NO
(default value)
Normally Open Output Signal.
NC
Normally Closed Output Signal.
Side switch (with in-
puts (3, 4)) in Disa-
bled mode
Door Open
(default value)
The door goes to Door Open mode in position (II) of the
side switch.
Door Closed
The door goes to Door Closed mode in position (II) of the
side switch.
I/O Con-
figuration
One-way
direction
Egress
(default value)
The operator works in Egress Only when one-way is
selected.
Ingress
The operator works in Ingress Only when one-way is
selected.
Emergency
Type of Signal:
- Impulse NO
- Continuous NO
- Impulse NC
- Continuous NC
-
Disabled
(default value)
C
ONTINUOUS
S
IGNAL
: enters "Emergency" status for the
duration of the signal. Once the signal has been disabled,
the door returns to the previous mode.
I
MPULSE
S
IGNAL
: enters "Emergency" status until Reset.
D
ISABLED
: emergency disabled (by default).
Type of Action
-
Door Open
(de-
fault value)
- Door Closed
- Manual
M
A N U A L
D
O O R
: a l l t h e p e r i p h e r a l s a r e d i s a b l e d
(electrolocks, hold-open systems, etc.), the motor is
released, and the door works as a non-motorised door.
D
OOR
O
PEN
/ D
OOR
C
LOSED
: the door goes to open or closed
position and remains in this status.
Advanced functions