330-In
st-Config
sw113
.fm - 29/4/21
INSTALLATION - DOOR CONFIGURATION
44
Installation guide
Automat-
ic Mode
(cont.)
Closing
Closing with Motor
The closing movement is carried out by the motor.
Closing with spring
(default value)
The closing movement is carried out by the spring.
Parameters can be configured to optimise closing (see
"Curve parameters").
Push&Go mode
Enable
- Enabled
-
Disabled
(default
value)
OPENING: starts by manually opening the door. The
operator will finish the opening operation automatically
when the door's opening angle exceeds a few degrees.
STANDBY: the door remains open for a programmed
time.
CLOSING: the closing operation starts automatically once
standby time is finished.
DISABLED: function disabled.
Degrees (0 to 45º,
default value:
0
)
Configure the opening degrees to start the motorised
opening movement.
Push&Close mode
Enabled
When open in Semi-Automatic mode, the operator starts
the closing movement if the door is pushed manually in
closing direction.
Disabled
(default value)
Function disabled.
Manual
Mode
Normal
(default value)
In manual mode the door works as a normal "door
closer".
•
OPENING: the door opens manually.
•
STANDBY: no standby time.
•
CLOSING: the compression spring closes the door.
Servo-assisted (0 to 5, default value:
0
)
The operator will assist with opening whenever door
movement is detected. The assistance level must be
adjusted for each facility.
Anti-
crushing
Sensitivity (1 to 10, default value:
5
)
Configure sensitivity level:
•
1: more sensitive level,
•
10: less sensitive level.
If the door collides with an obstacle during opening, it
reverses operation direction and closes slightly. The door
slowly opens to the full after a few seconds.
If the door collides with an obstacle during closing, it
reverses operation direction and opens completely at slow
speed. It then closes at slow speed.
Sensitivity
Mode
Normal mode
(de-
fault value)
Full Energy standard configuration.
In opening, it continues to open over and over again. In
closing, it continues to close over and over again.
Safe mode
Low Energy standard configuration.
If the obstacle continues, the door switches to MANUAL
MODE after five attempts.
Spring Closing
Enabled
Anti-crushing enabled in spring closing movement.
Disabled
(default value)
Anti-crushing disabled in spring closing movement.
Advanced functions