330-I
nstal_Electr
sw113.fm -
29/4
/21
Automatic swing door PREMIS 200
29
INSTALLATION - ELECTRICAL
6
ROTARY SELECTOR
To RESET, press the concealed
pushbutton to the right of the
exit only icon using a tipped
instrument.
It is not possible to configure any door
parameters with the rotary selector.
SET-UP: Press RESET for 5 sec.
LED:
- Normal operation: flashing 1 sec.
- Failure: fast flashing.
Door open
Door closed
Automatic
One direction
Manual mode
Winter (Double swing doors)