INSTALLATION - DOOR CONFIGURATION
Automatic swing door PREMIS 200
41
Opening
direction
(see
opening
direction
diagram,
page 51)
Right
Backing into the hinges will make the door open to the right.
Left
(default value)
Backing into the hinges will make the door open to the left.
Door
Charac-
teristics
Weight (50 to 250
kg, default value:
50
)
If the door is configured in LOW ENERGY mode, the drive parameters are
adjusted according to the specifications of the standard, taking into account the
weight and width values indicated.
Width (700 to 1400
mm, default value:
700
)
Electro-
lock
Type
Electro-
lock
Specific power supply device, intercom.
During opening: the operator powers the lock in order to release the latch, and
then stops powering the lock.
During closing and with the door closed: the operator does not power the lock.
Electro-
magnet
(Continuous power supply device)
During opening: the operator stops powering the lock, starting to open after a
while.
During closing: the operator does not power the lock.
During door closed: the operator constantly powers the lock in the following
modes: KC, Door Closed and Egress Only.
Disabled
(default
value)
(Door with no electrolock)
Voltage
24V
Power with 24V internal power supply.
12V
(default
value)
Delay in opening (0
to 10.000 msg,
default value:
0
)
Delay time, configurable from 0 to 10 seconds, between start of electrolock
release and start of the opening movement.
Opening force (0 to
5, default value:
0
)
Impulse level performed by the motor in closing direction in order to release the
electrolock. Increasing the value increases impulse power in closing direction.
Test
NO
Normally open signal with electrolock with no power.
NC
Normally closed signal with electrolock with no power.
Disabled
(default
value)
Electrolock with no test.
Basic functions
24V
12V
12V power by means of internal 24V power supply.
"Real" voltage can only be measured under load.