INSTALLATION - DOOR CONFIGURATION
Automatic swing door PREMIS 200
47
Temperatures
Motor temperature (-50 to
200ºC, default value:
100
)
Indicates the motor temperature and allows a limit to be
set.
Driver temperature (-50 to
200ºC, default value:
70
)
Indicates the driver temperature and allows a limit to be
set.
Min ambient temperature (-50
to 200ºC, default value: -
20
)
Indicates the minimum ambient temperature and allows a
limit to be set.
Max ambient temperature (-50
to 200ºC, default value:
70
)
Indicates the maximum ambient temperature and allows
a limit to be set.
Advanced functions
Sensors
Activation sensors
Interior
Configuration
-
NO
(default
value)
- NC
- Disabled
Activation valid for modes: AUTOMATIC, EGRESS ONLY,
SEMI-AUTOMATIC AND INTERLOCK.
•
NO
: Input Normally Open (default setting),
•
NC
: Input Normally Closed,
•
Disabled.
Courtesy
-
Disabled
(de-
fault
value)
- Enabled
The input can be configured as a Courtesy input:
Do not use Courtesy mode as activation for Semi-
automatic
Exterior
Configuration
-
NO
(default
value)
- NC
- Disabled
Activation valid for modes: AUTOMATIC, INGRESS ONLY,
SEMI-AUTOMATIC AND INTERLOCK
•
NO
: Input Normally Open (default setting),
•
NC
: Input Normally Closed,
•
Disabled.
Courtesy
-
Disabled
(de-
fault
value)
- Enabled
The input can be configured as a Courtesy input.
Do not use Courtesy mode as activation for Semi-
automatic.
Safety closing
sensors (SIS)
The safety
sensors
installed must
have a test
input to
monitor correct
operation. The
door switches
to MANUAL
MODE in the
event of test
failure.
Configuration The door continues to open if the closing safety device is enabled during
opening.
The door reverses operation direction and opens completely if the closing
safety device is enabled during closing. The door remains in this position until
the signal is disabled.
NC with no test
Normally closed with no test signal.
NC with test
Normally closed with test signal.
NO with test
Normally open with test signal.
Disabled
(default value)
Safety sensor in closing disabled.
Spring closing Disabled
Safety sensor in closing disabled.
Enabled
(default value)
Safety sensor in spring closing enabled in modes:
Automatic and Egress Only.