330-I
nst-Config sw11
3.fm - 29/4/21
INSTALLATION - DOOR CONFIGURATION
Automatic swing door PREMIS 200
45
Inputs/
Outputs
Inputs
(1,2,3,4)
Mode
Egress Only mode
The door only opens automatically in one direction
(ingress only or egress only, configurable). If the door has
an electrolock, it remains locked when closed.
The door can only be opened from the opposite
direction by an opening impulse (KB).
Partial Mode
Function specially designed for double swing doors.
Enabling this function generates an opening of the Master
operator only. In single doors, this activation is equivalent
to the KI or KA input.
Door Open mode
The door remains in maximum opening position for the
entire time.
Door Closed
Mode
After a period of delay, the door goes to door closed
position and remains closed, locking if it has an
electrolock.
The door can only be opened by an external opening
impulse (KB) or by changing mode from the selector.
Manual Mode
The door switches to Manual mode.
Automatic Mode
The door switches to Automatic mode.
Fire Door Mode
When the Fire Door signal is enabled, the operator
disconnects all peripherals and the motor, and the door
closes using the built-in spring. A RESET will be necessary
to re-enable the operator.
Hold-Open Mode
When the hold-open signal is enabled, the door switches
to open. When it reaches Door Open, the operator
powers the fastening devices and the motor is released
after a few seconds. The door remains open due to the
action of the fastening devices. Once the signal has been
disabled, the door returns to the previous mode.
Courtesy Mode
"Courtesy opening
for persons with disa-
bility"
When courtesy opening for persons with disability is
enabled, the door carries out an automatic opening and
closing cycle at suitable speed.
The speeds and standby time can be selected from the
digital selector.
Courtesy opening works in the following modes:
Automatic, One-Way and Manual.
Stop Mode
When this function is enabled, the motor is disabled and
the door switches to Manual mode. The door remains in
manual mode until the signal is disabled. At this moment
the door returns to the work mode prior to the Stop signal
being enabled. The assistance functions in Manual mode
are disabled (servo-assisted opening and closing with the
assistance of the motor).
Emergency
Lock Mode
If the emergency locking signal is enabled, the door
switches to closed and the electrolock, if fitted, is enabled.
Resetting is required to leave this function.
Lock toilet
Specific input for "accessible toilets".
(...)
(...)
(...)
Unlock toilet
Specific input for "accessible toilets".
Advanced functions