INSTALLATION - DOOR CONFIGURATION
Automatic swing door PREMIS 200
49
Power
(see power diagram,
page 51)
Door closed (0 to 10, default
value:
0
)
Level of resistance exerted by the motor for manual
opening in door closed position. Increasing the value
increases the resistance. Value 0 disables resistance
(default setting).
Spring assistance (0 to 10, default
value:
2
)
Assistance by the motor in closing whenever there is not
enough spring force to guarantee optimum closing (e.g.
due to wind, friction, etc). The motor assists in closing.
Increasing the value (from 0 to 10) increases the level of
assistance.
Spring assistance position (0 to
45º, default value:
10
)
Determines the position (from 5º to 45º) the "Spring
Assistance" function comes into action in.
Final impulse (0 to 10, default
value:
1
)
Increasing the value increases the motor's thrust power in
the last 5º. This parameter acts both on spring closing and
motor closing.
Impulse to release the motor (0 to
5, default value:
0
)
The motor is released if an external impulse is received.
•
Zero value disables this function (default setting).
•
Increasing the value increases the impulse intensity re-
quired to release the motor.
Disabling this function and configuring motor close
t o g u a r a n t e e c o n t r o l l e d m o v e m e n t s i s
recommended in windy locations.
Start spring closing (0 to 5,
default value:
0
)
Assistance by the motor in the first 10º of closing
whenever there is not enough spring force to guarantee
optimal start of closing. Increasing the value increases the
level of assistance.
Time selection
Normal Open time (0 to 60 sec,
default value:
1
)
Time the door remains open before start of closing
movement. (KI/KA activation).
Pulse Open time (0 to 60 sec,
default value:
1
)
Time the door remains open before start of closing
movement. (KB activation).
Courtesy Open time (0 to 60 sec,
default value:
1
)
Time the door remains open before start of closing
movement. (COURTESY activation).
Switch to Closed mode (0 to 300
sec., default value:
0
)
Delay time to switch to Closed mode.
Parameters curve
Installation Information
SAT information
Technical support information.
Installation ID
Identification for the facility.
Installation date
Date of installation.
Latest warnings
List of latest warnings.
Latest maintenance
List of maintenance carried out.
Sensor status
Sensor status in real time.