Automatic swing door PREMIS 200
31
INSTALLATION - ELECTRICAL
Connections diagram:
Opening impulse/Closing impulse (exterior key)
These are inputs which allow the doors to be opened
and closed outside of the work modes commonly
allowed by the mode selectors. The inputs are
impulsive. The function or behaviour of each input is as
follows:
Opening impulse function (KB)
: Each KB impulse
generates an opening of the door. When the opening
has been carried out the operator will return to the
previous operating mode.
Closing impulse function (KC)
: This input leads the
operator to close the door in night mode. Selectors and
programmable inputs are disabled in this mode. Each
KC input activation will take the door from its current
position to closed. Act on KB or opening impulse to
leave this mode.
Reset button
Enabling the signal directly resets the electronic plate's
microprocessor.
SAFETY SENSOR SIS
SAFETY SENSOR SIO
Do not connect power to the signal inputs.
To comply with the EN16005 standard, adjust the
sensor test according to the following diagram:
Connections
diagram
KB
KC
Connections diagram
RESET