background image

Blue Top Locking System Quick Start Guide

Summary of Contents for Blue Top Locking System

Page 1: ...Blue Top Locking System Quick Start Guide...

Page 2: ...order Page 4 Operating Options Page 5 Blue Top Order Form Page 6 Lock Connection Page 7 System Wiring schematic Page 8 Wiring Power Supply Page 9 Wiring Power Supply Page 10 Wiring of Opening Devices...

Page 3: ...is designed to be a brief version of the full Blue Top Operators Manual For any further or more comprehensive Information please refer to the manual or contact Winkhaus UK Ltd 1950 Kettering Parkway K...

Page 4: ...12 Push to open switch 9 Terminal block Auxiliary interface 8 Transformer 6 Access control Fob reader 7 Battery back up unit 6 1 Manual Override operating levers 5 Actuation Magnet 4 Centre keep 3 De...

Page 5: ...WH Door Push Pull Handles 9 WH Sender Remote Set 11 WH Transponder Set 10 A n other Other access control system Wired via WH Terminal Block Auxiliary interface 12 A n other Digital pad 16 WH Auxiliar...

Page 6: ...instead of a key fob and reader The receiver for the remote has added advantages in that the receiver can be located out of sight and also the two button remote can also be used to operate another sy...

Page 7: ...BM order form Blue Top Locking System...

Page 8: ...ugged into the lock motor housing via the blue male connector The other end wired into the Terminal block Auxiliary Interface using the appropriate colour coded terminals 17 20 as follows Blue Top Loc...

Page 9: ...ace is into which all wires are connected Blue Top Locking System Transponder reader 7 Terminal block Auxiliary interface 8 Day night switch 10 Open door switch 9 Cable and lock connector 8 1 8 2 24vd...

Page 10: ...block Auxiliary interface see diag 1 3 Connect fused spur to WH Transformer see diag 1 2 Run a 5amp x 240v fused spur to within 50mtrs of door 1 Connect transformer to BM BT terminal block Auxiliary i...

Page 11: ...Wiring Power Supply Fail Safe Blue Top Locking System...

Page 12: ...tch to terminals 9 10 of the Terminal Block Auxiliary Interface Push to open switch This should be a spring return rocker switch and should be wired to terminals 11 12 of the Terminal Block Auxiliary...

Page 13: ...mming card when used deletes all previously authorized key fobs To delete all key fobs present the Red programming card to the reader unit you will then hear one continuous beep for 1 secs which indic...

Page 14: ...continuous beep and the remote will be in teaching mode Then press the buttons you wish to enable you will hear continuous short beeps If buttons are not pressed whilst programming within 5 secs the...

Page 15: ...gram Fob Remote replace battery in remote Fob Remote not authorised Remote battery dead Does not operate with Fob Remote Switch to Night Mode Lock in Day Mode Does not throw Dead Bolts Open lock mecha...

Reviews: