C4 Maintenance 2. General Maintenance
8
C
Series Maintenance Manual Rev
.2
2.2 Overhaul (Parts Replacement)
CAUTION
■
If you do not overhaul properly, it may have a serious impact on safety.
■
Overhaul timing is based on an assumption that all joints are operated for equal
distance. If a particular joint has a high duty or high load, it is recommended to
overhaul all joints (as many as possible) before exceeding 20,000 operation hours
with the joint as a basis.
The parts for the Manipulator joints may cause accuracy decline or malfunction due to
deterioration of the Manipulator resulting from long term use. In order to use the
Manipulator for a long term, it is recommended to overhaul the parts (parts replacement).
The time between overhauls is 20,000 operation hours of the Manipulator as a rough
indication.
However, it may vary depending on usage condition and degree of the load (such as when
operated with the maximum motion speed and maximum acceleration/deceleration in
continuous operation) applied on the Manipulator.
For the EPSON RC+ 7.0 Ver. 7.2.x or later (firmware Ver.7.2.x.x or later), the
recommended replacement time for the parts subject to maintenance (motors, reduction
gear units, and timing belts) can be checked in the [Maintenance] dialog box of the
EPSON RC+ 7.0.
For details, refer to the following manual.
RC700 series Maintenance Manual 6. Alarm
Note:
The recommended replacement time for the maintenance parts is when it reaches the L10
life (time until 10% failure probability). In the [Maintenance] dialog box, the L10 life is
displayed as 100%.
NOTE
Summary of Contents for C Series
Page 1: ...Rev 2 EM221R5039F 6 Axis Robots C series Maintenance Manual ...
Page 2: ...Manipulator manual C4 series Maintenance Manual Rev 2 ...
Page 20: ...Table of Contents xviii C Series Maintenance Manual Rev 2 ...
Page 22: ......
Page 69: ...C4 Maintenance 4 Cable Unit C Series Maintenance Manual Rev 2 49 ...
Page 70: ...C4 Maintenance 4 Cable Unit 50 C Series Maintenance Manual Rev 2 ...
Page 72: ...C4 Maintenance 4 Cable Unit 52 C Series Maintenance Manual Rev 2 ...
Page 73: ...C4 Maintenance 4 Cable Unit C Series Maintenance Manual Rev 2 53 ...
Page 74: ...C4 Maintenance 4 Cable Unit 54 C Series Maintenance Manual Rev 2 4 2 2 Power Cable ...
Page 75: ...C4 Maintenance 4 Cable Unit C Series Maintenance Manual Rev 2 55 ...
Page 196: ......
Page 283: ...C8 Maintenance 4 Cable Unit C Series Maintenance Manual Rev 2 263 ...
Page 284: ...C8 Maintenance 4 Cable Unit 264 C Series Maintenance Manual Rev 2 ...
Page 286: ...C8 Maintenance 4 Cable Unit 266 C Series Maintenance Manual Rev 2 C8 A1401 C8XL ...
Page 442: ...C8 Maintenance 18 C8 Option Parts List 422 C Series Maintenance Manual Rev 2 ...
Page 444: ......
Page 516: ...C12 Maintenance 4 Cable Unit 496 C Series Maintenance Manual Rev 2 ...
Page 517: ...C12 Maintenance 4 Cable Unit C Series Maintenance Manual Rev 2 497 ...
Page 518: ...C12 Maintenance 4 Cable Unit 498 C Series Maintenance Manual Rev 2 4 2 2 Power Cable ...
Page 519: ...C12 Maintenance 4 Cable Unit C Series Maintenance Manual Rev 2 499 ...