4.2.26.3 Duplex Unit Board (PWB-AD) Removal
1. Remove the Board Cover. (See “Duplex Unit Board Cover Removal” on
page -176.)
2. Remove the harness from 3 connectors on the Duplex Unit Board (PWB-
AD).
3. Remove 2 screws securing the Duplex Unit Board (PWB-A).
Figure 4-68. Duplex Unit Board (PWB-AD) Removal
4.2.26.4 Motor Cover Removal
1. Remove 1 screw securing the Motor Cover.
2. Release 1 hook securing the Motor Cover to the Duplex Unit.
Figure 4-69. Motor Cover