EPSON AcuLaser C2000 / AcuLaser C1000
Revision E
Disassembly and Assembly
Disassembling Procedure
150
4.2.4.2 Controller Box Removal
1. Remove the Rear Right Cover.(See “Rear Left Cover Removal” on
page 147.).
2. Remove 8 screws securing the Control Box. (Note: 2 screws among 8
screws are securing both the Controller Box and the MCU.)
3. Remove the Controller Box.
Figure 4-18. Controller Box Removal
4.2.5 MCU (PWB-A Board) Removal
1. Remove the Rear Controller Cover. (See “Rear Controller Cover Removal”
on page -145.)
2. Remove the Rear Cover. (See “Rear Cover Removal” on page -146.)
3. Disconnect the twenty 9 connectors for the MCU and remove 3 screws
securing the MCU.
NOTE:
MCU is secured with 5 screws but two of them are removed when
the Controller Box is removed.
4. Remove the MCU by pulling it to the left making sure the connector on
Figure 4-19. MCU (Mechanical Controller Board) Removal