4.2.23 Fusing Mechanism
4.2.23.1 Pressure Roller Estrangement Sensor Removal
1. Remove the Fusing Pressure Motor. (See “Fusing Pressure Motor
Removal” on page -155.)
2. Remove 1 screw and 1 connector of the pressure roller estrangement
sensor.
Figure 4-62. Pressure Roller Estrangement Sensor Removal
4.2.24 Paper Eject Mechanism
4.2.24.1 Paper Eject Sensor Removal
1. Open the fusing cover.
2. Remove 4 screws securing the sensor support plate.
3. Remove 1 connector securing the paper eject sensor.
4. Release the paper eject sensor hook.
Figure 4-63. Paper Eject Sensor Removal