Chapter 7 Parameters
EMSD5 AC Servo Manual
78
(3) Corresponding functions for P3-17 is represented by 8-bit binary:
Number
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Function
NULL
JOGN
JOGP
INH
CLR
GEAR2
GEAR1
NULL
(4) Corresponding functions for P3-18 is represented by 8-bit binary:
Number
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Function
NULL POS2
POS1
POS0
CTRG
HOLD
NULL
NULL
(5) Corresponding functions for P3-19 is represented by 8-bit binary:
Number
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Function
NULL NULL
NULL
NULL
NULL
NULL
ORGP
SHOM
Parameter Meaning:
One of 5 parameters
Corresponding Function
Result
0
Unplanned
OFF
(
invalid
)
Already Planned
It is up to signals
1
Unplanned Or Already Planned
ON
(
forced valid
)
7.3 P4 Group Parameters For Internal Position Command
No.
Name
Function
Rang
Default
P4-0
Internal
position
instruction
control mode
0: absolute position instruction.
1: incremental position instruction.
0-1
0
P4-1
The digital
output delay
of internal
position
completion
1.
When the internal position command is
completed or stops,the output internal position
command completes (CMDOK) this DO signal
after the delay time set by P4-1.
2.
Only when the delay time P4-1=0 and
CMDOK=1 can it receive trigger internal position
command.
3.
Only when the delay time P4=1 is not 0 and
CMDOK=1 can it receive the internal position
command triggered by CTRG.
0-200ms
0
P4-2
The setting of
position
Cycle
numbers for
To set position cycles of the first internal position.
-30000-
30000
0
◆
Being planned means that the parameter has been selected by the input
terminal in the P3-0~P3-3.