The following sub-sections provide you with the initial display screen that appears for each configuration function.
Use the
flow diagram for ORP programming
at the end of Sec. 6 and the Model 1056 live screen prompts for
each function to complete configuration and programming.
6.3.2 Measurement
The display screen for selecting the measurement is
shown. The default value is displayed in
bold type
.
Refer to the pH/ORP Programming flow diagram to
complete this function.
6.3.3 Preamp
The display screen for identifying the Preamp location is
shown. The default value is displayed in
bold type
.
Refer to the pH/ORP Programming flow diagram to
complete this function.
6.3.4 Filter
The display screen for entering the input filter value in
seconds is shown. The default value is displayed in
bold type
. Refer to the pH/ORP Programming flow diagram
to complete this function.
A detailed flow diagram for ORP programming is
provided at the end of Sec. 6 to guide you through
all basic programming and configuration functions.
To configure the ORP measurement board:
1. Press
MENU
2. Scroll down to
Program
. Press ENTER.
3. Scroll down to
Measurement
. Press ENTER.
4. Select
Sensor 1
or
Sensor 2
corresponding to
ORP. Press ENTER.
The adjacent screen format will appear (factory defaults
are shown). To program any displayed function, scroll
to the desired item and press ENTER.
S1: 1.234µS/cm 25.0ºC
S2: 12.34pH 25.0ºC
S
N
Preamp
Analyzer
Sensor/JBox
S1: 1.234µS/cm 25.0ºC
S2: 12.34pH 25.0ºC
S
N
Input filter
04 sec
6.3.5 Reference Impedence
The display screen for Selecting Low or high Reference
impedance is shown. The default value is displayed in
bold type
. Refer to the pH/ORP Programming flow diagram
to complete this function.
S1: 1.234µS/cm 25.0ºC
S2: 12.34pH 25.0ºC
S
N
Reference Z
Low
High
S1: 1.234µS/cm 25.0ºC
S2: 12.34pH 25.0ºC
S
N
Configure
Measure: pH
Preamp: Analyzer
Flter: 4 sec
Reference Z: Low
S1: 1.234µS/cm 25.0ºC
S2: 12.34pH 25.0ºC
S
N
Measurement
pH
ORP
Redox
Ammonia
Fluoride
Custom ISE
Instruction Manual
LIQ-MAN-1056
Section 6.0: Programming the Measurements
April 2017
Summary of Contents for Rosemount 1056
Page 4: ...Quick Start Guide Figure A Quick Start Guide ...
Page 5: ...Quick Reference Guide Figure B Model 1056 Menu Tree ...
Page 28: ...20 Instruction Manual LIQ MAN 1056 Section 2 0 Installation April 2017 ...
Page 50: ...42 Instruction Manual LIQ MAN 1056 Section 6 0 Programming the Measurements April 2017 ...
Page 84: ...76 Instruction Manual LIQ MAN 1056 Section 6 0 Programming the Measurements April 2017 ...
Page 122: ...114 Instruction Manual LIQ MAN 1056 Section 7 0 Calibration April 2017 ...
Page 124: ...116 Instruction Manual LIQ MAN 1056 Section 8 0 Return of Material April 2017 ...