Appendix
EFORT INTELLIGENT EQUIPMENT CO.,LTD
251
4.There is too much
load.
1416
0x22000000
Axis %d
0x2310
Overcurrent
of the drive
U
1. The U-phase
output of the drive
is short-circuited;
2. The motor is
overloaded;
3. The drive is
damaged.
1.
Detect
U-phase
wiring;
2. Reduce the motor
load;
3. Repair or replace the
drive.
1417
0x22000000
Axis %d
0x2311
Overcurrent
of the drive
V
1. The V-phase
output of the drive
is short-circuited;
2. The motor is
overloaded;
3. The drive is
damaged.
1. Check the V-phase
wiring;
2. Reduce the motor
load;
3. Repair or replace the
drive.
1418
0x22000000
Axis %d
0x3210
Overvoltage
of DC bus
bar
1. The voltage of
the power supply is
too high;
2. The resistance
value of the braking
is too high.
1. Check the voltage of
the power supply;
2. Choose the proper
resistance.
1419
0x22000000
Axis %d
0xFF02
Continuous
overload of
the drive
1. Mechanical jam
occurs;
2. The drive is ov
erloaded;
3. The motor is
malfunctioning;
4. The drive is m
alfunctioning.
1. Check the mechanical
transmission part and
improve the mechanical
transmission
performance;
2. Check the load of the
motor, or increase the
capacity of the motor
drive module;
3. Repair or replace the
motor;