Monitor
EFORT INTELLIGENT EQUIPMENT CO.,LTD
205
3
1. After the variable value r
ewriting was confirmed, the
new value will be displayed
in the monitoring interface.
Profinet Protocols
The profinet function supports that a robot can be connected as a slave system, with
address 2, including 6 input blocks and 6 output blocks. Each block includes 32
bytes, and its data type is unsigned int
(
2byte
)
or float
(
4byte
)
.
The data storage uses Big-Endian mode, so that when a unsigned int type variable
being divided into byte type parts, the high-low bits conversion of data should be
noticed.
Note: The Profinet function only supports Robox RP2 Pro controllers! There is no
any content about the function to be displayed in the TPU interface for the Robox
RP2 Eco.
From PLC to Robot
In signal transport from PLC to Robot, the PLC is as sending end, and the robot is
as receiving end. Data received mainly include the system variables and the TPU
variables, where the Bus_Get[0]-Bus_Get[191] is 192 Byte as the data reception.
Table 7-5 The data receiving protocol of Profinet
Variable
Type
Physical Address
Unit
Bytes
Sub-Unit
Remark
System Va
riable
Bus_Get[0]-[1]
I16
2
BOOL
Bit0
:
Servo on /
off (Pulse)
Bit1: Running (P
ulse)
Bit2: Termination
(Pulse)
Bit3: Clear an al
arm (Pulse)
Bit4: Load a pro
gram (Pulse)
Bit5: Program re