Appendix
EFORT INTELLIGENT EQUIPMENT CO.,LTD
275
4909
0x220000
00
Failure in
reading the
auxiliary axis
parameter
file
Failing to read the
auxiliary axis
parameter file will
prompt an alarm.
Check if the
/Application/auxaxis/aux
pardata.xml file in the
card directory exists; if it
does not exist,
reconfigure the parameter
generation file.
4910
0x220000
00
Failure in
updating
the auxiliary
axis
parameter
file
Failing to update
the auxiliary axis
parameter file will
prompt an alarm.
Check whether the
/Application/auxaxis/aux
pardata.xml file in the
card directory exists and
whether it is saved
successfully. If it does
not exist, reconfigure the
parameter generation file.
4911
0x220000
00
Modification
to
configuration
parameters
under
power-on
Modification to
configuration
parameters under
power-on will
prompt an alarm.
Please click the save
button when the servo is
turned off manually.
4912
0x220000
00
The target
position
exceeds the
maximum
limit.
The target
position exceeds
the maximum
limit.
Check whether the target
position of single-step
operation exceeds the
limit, and whether the
auxiliary axis is cleared.
4913
0x220000
00
Failure in
opening the
parameter
file when
reading the
file
Fail to open the
parameter file
when reading the
file.
Check whether the
/Application/auxaxis/aux
pardata.xml file in the
card exists, and if it does
not exist, reconfigure the
parameter generation file.
4914
0x220000
00
Failure in
reading
auxiliary axis
Fail to read
auxiliary axis file.
Check whether the
directory
/Application/auxaxis/aux