Appendix
EFORT INTELLIGENT EQUIPMENT CO.,LTD
256
0xFF17
Negative
soft limit
e of the position
exceeds (negative
software limit val
ue + positioning c
ompletion threshol
d)
software limit function is
not needed, it can be
disabled by parameter
0x2000;
2. Check the planning
range of the position
command.
1438
0x22000000
Axis %d
0xFF23
Excessive
deviation of
power-on
position
When the drive is
powered on, the
saved location is
different from the
previous power-o
ff location and ex
ceeds the set thres
hold.
1. Check whether the
mechanical position has
changed, and confirm the
mechanical zero;
2. It can be cleared when
there is no abnormality.
1439
0x22000000
Axis %d
0xFF26
Illegal
modificatio
n to servo
parameters
The modified serv
o parameters exce
ed the limit value.
Modify the parameter
value
within
the
modifiable
range
of
servo parameters.
1440
0x22000000
Axis %d
0xFF0B
Overspeed
of the motor
1. The feedback s
peed exceeds the
preset speed, and
the error exceeds
threshold that has
been set;
2. The encoder is
abnormal.
1.
Optimize
the
parameters and control
parameters of the motor;
2. Check the settings and
wiring of the encoder.
1441
0x22000000
Axis %d
0xFF08
Failure in
disconnectio
n release
1. There is a mec
hanical jam;
2. The motor is o
verloaded;
3. The motor is
malfunctioning;
4. The drive is m
alfunctioning.
Check
the
2002h
collision