Appendix
EFORT INTELLIGENT EQUIPMENT CO.,LTD
257
1442
0x22000000
Axis %d
0x8130
Abnormalit
y in CAN
communicat
ion
heartbeat
Can communicatio
n is abnormal.
Check the connection
line between the Robox
controller and the drive.
1443
0x22000000
U Axis %d
0x2312
Overcurrent
of the drive
U
1. The W phase o
utput of the drive
is short-circuited;
2. The motor is o
verloaded;
3. The drive is da
maged
1. Detect the wiring of W
phase ;
2. Reduce the motor
load;
3. Repair or replace the
drive.
1444
0x22000000
Axis %d
0X7500
Failure in
Can
communicat
ion
Can node is close
d.
1. Check 120 matching
resistance;
2. Check the can line;
3. Check the source of
interference.
1497
0x22000000
CAN Open
Virtual node
does not
exist. Please
check the
wiring and
restart the
cabinet
CAN Open virtual
node does not ex
ist.
Check the CAN Open
wiring
between
the
Robox controller and the
IO board.
1498
0x22000000
Failure in
CAN Open
communicat
ion
1. Power off the r
obot body;
2. CAN Open nod
e is lost.
1. Check whether the
main body is powered
off;
2. Check whether the
CAN
Open
communication node is
lost.