![EFORT ECR5 User Manual Download Page 299](http://html.mh-extra.com/html/efort/ecr5/ecr5_user-manual_2367463299.webp)
Appendix
EFORT INTELLIGENT EQUIPMENT CO.,LTD
289
00
security: One
or more
security
planes are
compromised
security: One or
more security
planes are
compromised.
switched to manual mode
and the robot TCP is
moved away from the
security plane.
4978
0x220000
00
Unidentified
IO board
The controller
does not identify
the expansion IO
module.
Check whether the
expansion IO module is a
robot adaption type; if
not, please replace it.
4979
0x220000
00
The robot
stops running
at the
singularity
1. The robot
program goes
through a
singularity.
2. When the robot
is jogged, the
singularity is
approached.
1. Please teach the
program again to avoid
the singularity of the
robot.
2. Avoid singularities, or
switch to moving the
robot in the joint space.
4980
0x220000
00
Bending: The
thickness of
the
workpiece is
unqualified.
Bending: The
thickness of the
workpiece is
unqualified.
Please check the number
of workpiece and
reposition them.
4981
0x220000
00
Bending: The
bending
knife speed is
illegal.
Bending: The
bending knife
speed is illegal.
Please reconfigure the
bending knife speed.
4982
0x220000
00
Kinetics:
Failure in
updating
friction
parameters
1. The program
has not been
running when the
friction is
updated;
2. Load cannot be
installed when
friction is
updated;
1. Keep the robot
program running when
the friction parameter is
updated;
2. Remove the load and
cancel the load setting;
3. Increase the
magnification to more