Settings
EFORT INTELLIGENT EQUIPMENT CO.,LTD
145
Figure 5-38 TCP/IP Communication
Figure 5-39 Digital input port mode communication
Area parameters: each area has a parameter. The protection area corresponds to
the stop time and the warning area corresponds to the speed magnification. The stop
time represents the time required for the robot to stop, and the fastest is 0.2s. The
speed magnification indicates that when the area is triggered, the robot decelerates
to the magnification set by the user. If both alert 1 and alert 2 are enabled, the
magnification of alert 1 shall be less than Alert 2, otherwise an error will be
prompted.
Region type: up to three regions can be set. Tick the required region. The
corresponding region parameters cannot be set for the unchecked region. The area
includes protection, alert 1 and alert 2, as shown in Figure 5-40 below.
Prote
ction
Wa