11.32.7
Functional Variations of the Light Barrier Input
Function
with
or
without
control panel
Parameter
Selection of the input function on socket B18/5
239
If the light barrier function is not used, a switching function can be assigned to the input on socket B18/5 as well as to
inputs in1...i10.
The following input functions are possible with parameter 239:
Parameter 239 = 0
Light barrier function:
The input is prepared for a light barrier function.
Parameter 239 = 1...47
All other input functions are identical with those described for parameter 240 below.
11.33 Switching Functions of Inputs in1...i10
Function
with
or
without
control panel
Parameter
Selection of the input function
(in1...i10)
240...249
A variety of functions can be selected for each input on sockets ST2 and B4.
The following input functions are possible with parameters 240...249:
240 = 0
Input function blocked
240 = 1
Needle up/down:
Upon pressing the key, the drive runs from position 1 to position 2 or from position 2
to position 1. If the drive is not in the stop position, it runs to the preselected basic position.
240 = 2
Needle up:
Upon pressing the key, the drive runs from position 1 to position 2.
240 = 3
Single stitch (basting stitch):
Upon pressing the key, the drive performs one rotation from position 1 to
position 1. If the drive is in position 2, it runs to position 1 upon pressing the key and from position 1 to
position 1 each time the key is pressed again.
240 = 4
Full stitch:
Upon pressing the key, the drive performs a full rotation depending on the set stop position.
240 = 5
Needle to position 2:
If the drive is not in position 2, it runs to position 2 upon pressing the key.
240 = 6
Machine run blockage effective with open contact:
Upon opening the switch, the drive stops in the
preselected basic position.
240 = 7
Machine run blockage effective with closed contact:
Upon closing the switch, the drive stops in the
preselected basic position.
240 = 8
Machine run blockage effective with open contact (unpositioned):
Upon opening the switch, the drive
stops immediately unpositioned.
240 = 9
Machine run blockage effective with closed contact (unpositioned):
Upon closing the switch, the drive
stops immediately unpositioned.
240 = 10
Run at automatic speed (n12):
Upon pressing the key, the drive runs at automatic speed. The pedal is
not used. (This input function is inverted in mode 9.)
240 = 11
Run at limited speed (n12):
Upon pressing the key, the drive runs at limited speed. The pedal must be
pressed forward.
240 = 12
Sewing foot lifting with pedal in position 0 (neutral)
240 = 13
High lift for walking foot operational mode not stored:
The signal “high lift for walking foot” is issued
as long as the key is pressed down, and the drive runs with speed limitation (n10).
240 = 14
High lift for walking foot operational mode stored /flip-flop 1:
The signal “high lift for walking foot”
is issued upon briefly pressing the key, and the drive runs with speed limitation (n10). The operation is
disabled upon pressing the key again.
240 = 15
Tape cutter or fast scissors (mode 6/7):
Upon pressing the key, the tape cutter will be enabled for a
preset time.
240 = 16
Intermediate backtack / Intermediate stitch condensing:
Upon pressing the key, the backtack or stitch
condensing will be enabled anywhere in the seam and at standstill of the drive.
240 = 17
Stitch regulator suppression / recall:
Upon pressing the key, the backtack or stitch condensing
operation will be suppressed or recalled once.
240 = 18
Unlocking the chain:
Upon pressing the key, the motor performs a reverse rotation at the seam end.
Moreover, backtacking and thread trimmer will be suppressed.
240 = 19
Reset bobbin thread monitor:
After inserting a full bobbin, the stitch counter is set to the value
determined by means of parameter 031.
240 = 20
Handwheel running in the direction of rotation:
Upon pressing the key, the drive runs in the direction