EFKA FP220A5911
17
6.3.3 Parameter Selection with the +/- Keys
1.
After code number input at the
2.
Select the next parameter by pressing the
+
key
programming level
3.
Select the previous parameter by
4.
After pressing the
E
key, the
pressing the - key
parameter value is displayed
These values are saved when you start sewing. They remain in effect even after turning the machine off!
Using parameter 401 is another possibility for immediate storage without having to start sewing.
6.3.4 Immediate Storage of All Changed Data
Functions
Parameter
Immediate storage of all changed data
(EEP)
401
!
Input code number 3112 after power On
"
Taste
E
betätigen
!
Input parameter 401
"
Taste
E
betätigen
!
Set display from
0
to
1
"
Taste
E
oder
P
betätigen
!
All data are stored!
1 0 / K L2 3 2 5
P
E
P
E
1 1 / K L2 3 2 6
P
E
P