EFKA FP220A5911
12
5 Connection of Stepping Motor Controls to the FP220A Control
*) Front view of the socket (component side) and/or rear view of the plug (soldering side)
5.1 SM210A Control Settings for Operating the FP220A Control
!
Parameter 290 = 10
In mode 10, the SM210A control operates as slave.
!
Parameter 272 = 2
#2 = SCI stepping motor control address. All additional controls have higher addresses
(..#3, #4, etc.)
!
Parameter 270 = 560
Baud rate
!
Parameter 401 = 1
Immediate storing of the settings in the EEPROM.
5.2 FP220A Control Settings
!
Parameter 401 = 1
Immediate storing of the settings in the EEPROM.
ATTENTION
Turn on the FP220A / FP320A control together with the connected SM210A controls
by means of one mains switch.
Place a jumper between pin 2 and pin 3 on socket B19 of the last SM210A stepping
motor control.
Nr. 1113172
B776
B80
B2
Nr. 1113172