Parameter 193 = 0
Thread tension release and chain suction after the light barrier compensating stitches.
Parameter 193 = 1
Chain suction from light barrier uncovered onwards and thread tension release after the light barrier
compensating stitches.
Parameter 199 = 0
Thread tension release On at the seam end until pedal in pos. 0 (neutral).
Parameter 199 = 1
Thread tension release On at the seam end or at the start of the seam.
Parameter 199 = 2
Thread tension release On at the seam end or at the start of the seam and after “power On“.
Parameter 235 = 0
Braking curve Off.
Parameter 235 = 1
Braking curve On for precise stop upon chain suction at the seam end.
It is possible to select the speed function for stitch counting at the start of the seam and at the seam end by means of the
following parameters.
Parameter 143 = 0
Speed controllable by the pedal up to the set maximum speed (parameter 111).
Parameter 143 = 1
Fixed speed (parameter 112) without influence by the pedal. Stop with pedal in pos. 0 (neutral).
Parameter 143 = 2
Limited speed (parameter 112) controllable by the pedal up to the set limit.
Parameter 143 = 3
At fixed speed (parameter 112), can be suspended or interrupted depending on the setting of
parameter 019.
Parameter 144 = 0
Speed controllable by the pedal up to the set maximum speed (parameter 111).
Parameter 144 = 1
Fixed speed (parameter 113) without influence by the pedal. Stop with pedal in pos. 0 (neutral).
Parameter 144 = 2
Limited speed (parameter 113) controllable by the pedal up to the set limit.
Parameter 144 = 3
At fixed speed (parameter 113), can be suspended or interrupted depending on the setting of
parameter 019.
11.23.2
Start and End Counts
Function
with
or
without
control panel
Parameter
End count (c2) at limited speed n4 until stop
(c2)
000
Start count (c1) at limited speed n3 for chain suction
(c1)
001
Count (c3) tape cutter at the start of the seam
(c3)
002
End count (c4) for tape cutter at the seam end
(c4)
003
Seam end in mode 7 through end count (c2) or (c4)
(MHE)
191
Stitch counting speed at the start of the seam
(n3)
112
Stitch counting speed at the seam end
(n4)
113
The following settings are possible for determining the seam end by means of parameter 191:
Parameter 191 = 0
Seam end after count c4 (tape cutter)
Parameter 191 = 1
Seam end after count c2 (chain suction)
11.24 Function of Output Signal M8
Function
with
or
without
control panel
Parameter
Functions of signal M8
(m08)
296
The following settings are possible using parameter 296:
Parameter 296 = 0
Function signal M8 Off
Parameter 296 = 1
Signal M8 “hemmer foot” is On at the start of the seam with pedal in pos. <0 and in the seam with
signal “machine running”.
Parameter 296 = 2
Signal M8 “hemmer foot” is On at the start of the seam with pedal in pos. <0 and always in the
seam.
Parameter 296 = 3
Signal M8 enabled as “center cutter“.
Parameter 296 = 4
Signal M8 is On with “needle up / down“.
Parameter 296 = 5
Signal M8 alternates with M3 when set as “fast scissors“ on overlock machines (parameter 290 = 16
and parameter 232 = 1).