EFKA FP220A5911
69
!
When using the V810 control panel, parameter 291 will automatically be set to slide-in strip "
7
" if 290 = 7.
!
When using the V820 control panel, parameter 292 will automatically be set to slide-in strip "5" if 290 = 7.
Function
with
control panel
V810
V820
Tape cutter/Fast scissors
at the start of the seam On
lefthand arrow above key On
2 key
4 key
Tape cutter/Fast scissors
at the seam end On
righthand arrow above key On
Tape cutter/Fast scissors
at the start and at the end
both arrows above key On
of the seam On
Tape cutter/Fast scissors
at the start and at the end
both arrows above key Off
of the seam Off
The tape cutter signal can be influenced by parameter 020 in such a way that the signal remains on at the seam end and is
off when you start sewing again after some run-out stitches, which can be set by means of parameter 021. This action
serves as clamp.
Function
with
or
without
control panel
Parameter
Clamp at the seam end (output ST2/27) On/Off (mode 7)
(kLm)
020
Run-out stitches (ckL) of the clamp at the start of the seam (mode 7) or
(ckL)
021
stitch counting after light barrier uncovered until tape cutter On (mode 15)
Output and Times for Tape Cutter
Function
with
or
without
control panel
Parameter
Delay time for output M3 (ST2/27)
tape cutter
AH
(kd3)
284
ON period for
output M3 (ST2/27)
tape cutter
AH
(kt3)
285
!
Parameter
232
must be set at "
0
".
!
The delay time for the tape cutter is usually set at "0".
Output and Times for Fast Scissors
Function
with
or
without
control panel
Parameter
Delay time for output M3 (ST2/27)
fast scissors
AH1
(kd3)
284
ON period for output M3 (ST2/27)
fast scissors
AH1
(kt3)
285
Delay time for output M4 (ST2/36)
fast scissors
AH2
(kd4)
286
ON period for output M4 (ST2/36)
fast scissors
AH2
(kt4)
287
!
Parameter
232
must be set at "
1
".
!
The delay times for "fast scissors" are usually set at "0".
11.26.3
Functions for Mode 15
Function
without
control panel
Parameter
Count c1 and c2 On/Off
LED 1/2
S2 key
Counts c3 and c4 On/Off
LED 3/4
S3 key
Functions of sewing foot lifting On/Off
LED 5/6
S4 key
Basic position 1 or 2
LED 7/8
S5 key
!
The
tape cutter
signal can be set separately for start and end counting.
!
When using the V820 control panel, parameter 292 will automatically be set to slide-in strip "5" if 290 = 15.