EFKA FP220A5911
68
11.25 Function of Output Signal M11
Function
with
or
without
control panel
Parameter
Functions of signal M11
(m11)
297
The following settings are possible using parameter 297:
Parameter 297 = 0
Function according to setting of parameter 290
Parameter 297 = 1
Signal M11 is On whenever the light barrier is uncovered.
Parameter 297 = 2
Signal M11 is On whenever the light barrier is covered.
Parameter 297 = 3
Signal M11 is On only after light barrier uncovered or covered until seam end.
Parameter 297 = 4
Signal M11 is On as with setting 3. Signal M5 (machine running), however, is Off while signal M11
is On.
11.26 Tape Cutter/Fast Scissors (Modes 6/7/15/16)
11.26.1
Functions for Mode 6
The signal
tape cutter/fast scissors
is issued only at the seam end. A manual tape cutter/fast scissors can also be set. See
also chapter "
Manual
Tape Cutter/Fast Scissors
".
Function
with
or
without
control panel
Parameter
Tape cutter
at the seam end On/Off
014
Output and Times for Tape Cutter
Function
with
or
without
control panel
Parameter
Delay time for output M3 (ST2/27)
tape cutter
AH
(kd3)
284
ON period for
output M3 (ST2/27)
tape cutter
AH
(kt3)
285
!
Parameter
232
must be set at "
0
".
!
The delay time for the tape cutter is usually set at "0".
Output and Times for Fast Scissors
Function
with
or
without
control panel
Parameter
Delay time for output M3 (ST2/27)
fast scissors
AH1
(kd3)
284
ON period for output M3 (ST2/27)
fast scissors
AH1
(kt3)
285
Delay time for output M4 (ST2/36)
fast scissors
AH2
(kd4)
286
ON period for output M4 (ST2/36)
fast scissors
AH2
(kt4)
287
!
Parameter
232
must be set at "
1
".
!
The delay times for "fast scissors" are usually set at "0".
11.26.2
Functions for Mode 7
The signal
tape cutter/fast scissors
can be set separately for start and end counting. See also chapter "
Manual
Tape
Cutter/Fast Scissors
".
Function
without
control panel
Control
Tape cutter/Fast scissors
at the start of the seam On
LED 3 On
S3 key
Tape cutter/Fast scissors
at the seam end On
LED 4 On
Tape cutter/Fast scissors
at the start and at the end of the seam On
LED 3 and 4 On
Tape cutter/Fast scissors
at the start and at the end of the seam Off
LED 3 and 4 Off