31
Figure 16: Current behaviour in the uncontrolled phase
Conventional method:
Symmetrical control with high DC components
New process from Eaton (Moeller):
Asymmetrical control without DC components
→
With single-phase connected three-phase motors with
capacitors (Steinmetz circuit), system conditions always cause
an elliptical rotating field which cannot be completely
compensated by the asymmetrical trigger control.