9 Appendix
9.3 Specific technical data
DS7 Soft starter
09/16 MN03901001Z-EN
www.eaton.com
217
9.3.2 Terminal capacity, control cables, actuating circuit
The following technical data depends on size.
Size
Unit
Frame size 1:
4 - 12 A
Frame size 2:
16 - 32 A
Frame size 3:
41 - 100 A
Frame size 4:
135 - 200 A
General
Dimensions (W x H x D)
mm
45 x 130 x 95
45 x 150 x 118
93 x 175 x 139
108 x 215 x 178
Weight
kg
0.35
0.4
1.8
3.7
Terminal capacity
Cables
(box terminal)
Solid
mm
2
1 x (0.75 - 4)
2 x (0.75 - 2.5)
1 x (0.75 - 16)
2 x (0.75 - 10)
1 x (25 - 70)
2 x (6 - 25)
1 x (4 - 185)
2 x (4 - 70)
Flexible with ferrule
mm
2
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
1 x (0.75 - 16)
2 x (0.75 - 10)
Stranded
mm
2
1 x 16
2 x 16
1 x (25 - 70)
2 x (6 - 25)
1 x (4 - 185)
2 x (4 - 70)
Solid or stranded
AWG
1 x (18 - 10)
2 x (18 - 10)
1 x (14 - 8)
2 x (14 - 8)
1 x (12 - 2/0)
1 x (12 - 350 mcm
2 x (12 - 00)
Flat conductor
minimum
mm
2 x 9 x 0.8
2 x 9 x 0.8
maximum
mm
9 x 9 x 0.8
10 x 16 x 0.8
Tightening torque
Nm
1.2
3.2
9 (> 10 mm²)
6 (
≦
10 mm²)
14 (> 10 mm²)
5 (
≦
10 mm²)
Control cables
Solid
mm
2
1 x (0.75 - 4)
2 x (0.75 - 2.5)
1 x (0.75 - 4)
2 x (0.75 - 1.5)
1 x (0.75 - 4)
2 x (0.75 - 1.5)
1 x (0.75 - 4)
2 x (0.75 - 1.5)
Flexible with ferrule
mm
2
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
1 x (0.75 - 2.5)
2 x (0.75 - 1.5)
1 x (0.75 - 2.5)
2 x (0.75 - 1.5)
1 x (0.75 - 2.5)
2 x (0.75 - 1.5)
Stranded
mm
2
Solid or stranded
AWG
1 x (18 - 10)
2 x (18 - 10)
1 x (18 - 14)
2 x (18 - 16)
1 x (18 - 14)
2 x (18 - 16)
1 x (18 - 14)
2 x (18 - 16)
Tightening torque
Nm
1.2
0.6
0.6
0.6
Screwdriver (flat blade)
mm
0.6 x 3.5
0.6 x 3.5
0.6 x 3.5
0.6 x 3.5
Actuating circuit
Relay outputs
Number
1 (TOR)
2 (TOR,
RUN/READY)
1)
2 (TOR,
RUN/READY)
1)
2 (TOR,
RUN/READY)
1)
Max. voltage range
V AC/DC
= U
s
250
250
250
Max. load current
A
1
1
1
1
1) Does not apply for soft starter DS7 with SmartWire-DT (DS7-…-D).
Summary of Contents for DS7 Series
Page 1: ...Manual DS7 Soft starter 09 16 MN03901001Z EN...
Page 4: ...II...
Page 36: ...1 Device series DS7 1 14 Function 32 DS7 Soft starter 09 16 MN03901001Z EN www eaton com...
Page 96: ...3 Installation 3 6 Insulation test 92 DS7 Soft starter 09 16 MN03901001Z EN www eaton com...
Page 188: ...8 SmartWire DT 8 9 Programming 184 DS7 Soft starter 09 16 MN03901001Z EN www eaton com...