The power connection for the device fan is connected on the soft starter’s
bottom (right-hand side, above motor connection terminal 6T3). In order to do
so, you will first have to break out the cover for the plug connection that is
found on the housing.
▶
Carefully insert a standard screwdriver (size 2.5 × 0.4 mm) into the
opening to the left of the square cover [1] (to a depth of about 3 mm).
Figure 46: Insert standard screwdriver into opening.
▶
Pry out the cover [2].
Figure 47: Loosen cover
▶
Remove the released blanking plate [3].
Figure 48: Remove the cover
→
The blanking plate can not be refitted.
If you remove the device fan, make sure to cover the plug
connection with a suitable material (by masking it with electrical
tape, for example).