S e c t i o n 2 . 3 : C ha ng i ng O t he r N T 9 0 1 0 Fu n c t i o n s
3 9
NOTE:
The 3rd telephone Number will NOT back up the 2nd telephone
Number.
If Alternate Dial is enabled the system will alternate between the 1st and 3rd tele-
phone numbers when attempting to call the central station. If disabled the system will
only attempt to call the 3rd telephone number after failing to communicate on the 1st
telephone number.
NOTE:
For Alternate Dial to work properly the 3rd telephone Number must
be both enabled and programmed.
Telephone numbers can be up to 32 digits which will allow you to add special digits if
required. To program the telephone number enter numbers 0 through 9 as required.
The following is a list of HEX digits which can also be programmed and the function
they perform:
HEX (B)
- simulates the [
✱
] key on a Touch-Tone telephone
HEX (C) - simulates the [#] key on a Touch-Tone telephone,
or end of telephone number marker
HEX (D) - forces the system to search for dial tone
HEX (E)
- forces the system to pause for 2 seconds
HEX (F)
- end of telephone number marker
1st telephone number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [301]
2nd telephone number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [302]
3rd telephone number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [303]
3rd telephone number enable . . . . . . . . . . . . . . . . . . . . . Section [380], Option [5]
Alternate Dial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [380], Option [6]
2.3.10Communicator
Account Codes
The system Account Codes will be used by the NT9010 when communicating system
events (e.g. Low Battery, Test Transmission). This account code can be up to four digits
in length.
You can program two account codes: one for the first and third telephone numbers,
and one code for the second telephone number. You can also program the Telephone
Number 1/3 Account Code in Flash Programming (see the
Quick Set Up Guide
).
Telephone Number 1/3 Account Code . . . . . . . . . . . . . . . . . . . . . . . . Section [310]
Telephone Number 2 Account Code . . . . . . . . . . . . . . . . . . . . . . . . . Section [311]
2.3.11Communicator
Reporting
Formats
You can program the NT9010 system to report events using any one of the 5 formats
available. The system can report using different formats for Telephone Numbers 1/3,
and for Telephone Number 2. The following formats are supported: Pulse (20bps),
Contact ID, SIA, and a Pager format. The following is a description of each.
Communicator Format Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [350]