Section 1.3: Troubleshooting
1.3.1 Typical
Installation
Problems and
Solutions
When I try a placement test I get no result or “Bad” results.
Check the following:
• Are you testing the correct zone?
• Was the correct serial number entered when the device was enrolled?
• Is the device in range of the NT9010? Try testing the device in the same room as the
NT9010.
• Are you testing the zone correctly? (See the
Installation Instruction
sheet for each
device for testing instructions.)
• Are the batteries working and installed correctly?
• Are there any large metal objects that may be preventing the signal from reaching
the NT9010?
The device must be located where at least three “Good” results are obtained. If several
devices show “Bad” results, or if wireless keys operate inconsistently, you may need to
move the NT9010. See
1.2.2 Create an Installation Plan
on page 5 for tips on choosing
a mounting location for the NT9010.
The LED on the motion detector does not turn on when I walk in front
of the unit.
The LED is for walk test purposes only. See your
WLS904-433, WLS904PL-433 or WLS914-
433 Installation Instruction
sheet for walk test instructions.