S e c t i o n 2 . 2 : C ha ng i n g H o w t h e N T 9 0 1 0 W o r k s F o r U s e r s
3 1
3. Enter the 2-digit code from the list below for the function you want the button to
have:
4. Repeat steps 1 to 3 until all buttons are programmed.
* Do not use for UL Listed installations
NOTE:
Control unit must have the ‘Arm/Disarm Bell Squawk’ feature enabled
when using wireless key devices. When placing the control unit, ensure the bell
squawk can be heard from outside the home.
Wireless Key Function
Button Programming . . . . . . . . . . . . . . . . . . . . . . Sections [804]-[61] to [804]-[64]
WLS Key Does Not Use Access Codes . . . . . . . . . . . . . . . .Section [017], Option [1]
2.2.12Fire, Auxiliary
or Medical,
and Panic
Keys
Three emergency keys are available on the NT9010. Each pair of keys must be pressed and
held for 2 seconds before they will activate. This 2 second delay is designed to help prevent
accidental activation. If the
Fire Keys
option is enabled, when the Fire keys are pressed and
held for 2 seconds, the system will activate the alarm output. It pulses one second on, one
second off only if option 8 of Section [013] is disabled (Standard Fire option). If
Fire Bell
Continuous
is selected the alarm output will sound until a code is entered; otherwise it will
sound until a code is entered or the alarm output times out. Communication of the signal
to central station is immediate.
If the Auxiliary (
) or Medical (
)* keys are pressed and held for 2 seconds, the unit
beeps three times to verify activation. The system will beep the keypad ten times rapidly to
verify communication to the central station.
If the
Panic keys are pressed and held for 2 seconds, the system will immediately communi-
cate the signal to central station. If
Panic Keys Audible
is enabled, the system will beep
the keypad three times upon activation and activate the alarm output until a code is
entered or the alarm output times out. Otherwise the alarm will be completely silent.
NOTE:
The Fire, Auxiliary or Medical, Panic keys will operate even if Keypad
Lockout is active (see 2.2.13 Keypad Options on page 32).
Fire Keys Enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Section [015], Option [1]
Panic Keys Audible . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Section [015], Option [2]
Fire Bell Continuous . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Section [014], Option [8]
*If the unit is to be used in home health care applications, the unit must have Medical ( )
keys and not Auxiliary (
) keys.
Entry Description
00
Null Key (Key not used)
03
Stay Arm
04
Away Arm
05
No entry delay arming*
06
Door Chime On/Off
07
System Test
16
Quick Exit
17
Activate Stay/Away Zones
27
Disarm (Off)
28
Fire Alarm*
29
Auxiliary or Medical Alarm
30
Panic Alarm