zone is used for interior protection devices, such as motion detectors, and will
help prevent false alarms since it will always provide the user the entry delay time
to turn off the system.
[07] - [09] For Future Use
[10]
24 Hour Supervisory Buzzer Zone:
Whether armed or disarmed, when this
zone type is violated the system will immediately latch the keypad buzzer until a
valid access code is entered and will communicate immediately to the central
station.
[11]
24 Hour Burglary Zone:
If this zone is violated, whether armed or disarmed, the
system will immediately latch the alarm output and communicate to the central sta-
tion. The alarm will sound for the Bell Cutoff time programmed in Section [005]
“System Times” or until a valid access code is entered.
[12]-[20]:
The following zone definitions operate similar to the 24 Hour Burglary except for
System Event output type, SIA identifier, and some zone attributes:
[12] 24 Hour Holdup Zone
[13] 24 Hour Gas Zone
[14] 24 Hour Heat Zone
[15] 24 Hour Medical Zone
[16] 24 Hour Panic Zone
[17] 24 Hour Emergency Zone
[18] 24 Hour Sprinkler Zone
[19] 24 Hour Water Flow Zone
[20] 24 Hour Freezer Zone
NOTE:
[12] 24 Hour Holdup zones give a silent alarm by default.
[21]
24 Hour Latching Tamper:
If this zone is violated the installer must enter
Installer Programming before the system can be armed. The bell output will also
activate for the programmed time and the system will communicate the alarm.
[22]
Momentary Keyswitch Arm Zone:
Momentary violation of this zone will
alternately arm/disarm the system.
[23]
Maintained Keyswitch Arm Zone:
When this zone is violated, the system will
arm. When this zone is secured, the system will disarm.
NOTE:
Do not program wireless zones as [22] or [23] Keyswitch zones.
[24]
For Future Use
[25]
Interior Delay Zone:
When the system is fully armed (i.e. away armed), this
zone will follow the exit delay. It will also follow the entry delay, provided that a
delay zone is tripped first. If the delay zone is not tripped first, a zone defined as
“Interior Delay” will go into alarm instantly. When the system is stay armed, this
zone will be active, but when it is tripped, it will initiate the entry delay.
[87]
Delayed 24 Hour Fire (Wireless):
If this zone is violated (e.g. the smoke
detector senses smoke), the alarm will immediately sound, but the alarm com-
munication to the central station will be delayed for 30 seconds. If during the 30
second delay the user presses the [#] key, the alarm and communicator will be
delayed an additional 90 seconds. This provides time for a user to correct the
problem.