Operating Manual
© Dürr Systems AG
EcoBell2 SL EC - Rotating Atomizer with External Charging
Dismantling and Disposal
Document No.: MRA00001EN
Version:: 07
•
As of:: 01/2020
139 / 156
If the bell disk rubs against the shaping air ring, then atomizer body,
shaping air ring and bell disk should be disassembled and are
reassembled.
Then check the distance again.
The atomizer should not be operated with a rubbing bell disk.
Finally, the following work should be executed:
- Clean the entire atomizer by hand with isopropyl alcohol.
- Check that the atomizer is assembled completely.
- Ensure that there are no loose objects (tools, spare parts, cloths) in
the cabin.
- Rinse the atomizer.
Only then the atomizer should be used.
Pos: 71 /INP/ Bell2/09_00 Demo ntage, Entso rgung_AA @ 57\mod_1505984556028_20. docx @ 621503 @ 12222 @ 1
10
Dismantling and Disposal
10.1
Switching off the atomizer
Personnel:
- Electrician
Protective equipment:
- Protective workwear
- Protective gloves
- Safety boots
C A U T I O N
Danger to life due to high voltage
There is danger to life due to high voltage when approaching the
atomizer with external charging.
Prior to start of the operation, switch off the atomizer and secure it
against restart.
Brush the atomizer against the grounding rod in order to remove the
residual charge.