Operating Manual
© Dürr Systems AG
EcoBell2 SL EC - Rotating Atomizer with External Charging
Safety
Document No.: MRA00001EN
Version:: 07
•
As of:: 01/2020
13 / 156
Recommended components
- Generator
- Controller
- Wiring board
- R/O converter
The optical electrical converter (R/O converter) used for sensing
speed must conform to the “optical radiation (op)” ignition protection
category according to EN 60079-28 or IEC 60079-28.
1.6.3
Available device combinations
-
Eco
Bell2 SL EC
-
Eco
Bell2 SL EC with “
Eco
AUC” control system
- Total system with
Eco
RP 10 R1100
1.6.3.1
Eco
Bell2 SL EC
The
Eco
Bell2 SL EC includes the atomizer and the necessary
components. The atomizer must be integrated in a painting system
according to the technical data and the intended use. The conditions
for type testing are not fulfilled.
1.6.3.2
Eco
Bell2 SL EC with “
Eco
AUC” control system
The “
Eco
AUC” control system with integrated high voltage supply
controls and monitors the
Eco
Bell2 SL EC. If this combination is
integrated in a painting system
according to the technical data and the
intended use, the conditions of type testing are fulfilled.
1.6.3.3
Total system
Eco
RP 10 R1100
The total system comprises the following components:
-
Eco
Bell2 SL EC
- Robot
Eco
RP 10 R1100
- AUC control cabinet with integrated high voltage supply for the
atomizer
- Robot control
The total system
Eco
RP 10 R1100 fulfills the conditions for type
testing with regard to the atomizer.
Pos: 6 /INP/Be ll2/02_00 Siche rheit @ 57\mod_1508830857601_20. docx @ 622229 @ 1 @ 1
2
Safety