Operating Manual
© Dürr Systems AG
EcoBell2 SL EC - Rotating Atomizer with External Charging
Appendix
Document No.: MRA00001EN
Version:: 07
•
As of:: 01/2020
153 / 156
Grounding
Limit value
Measured value
Conveyor / goods carriers <> moving machine
<2Ω
●
Moving machine <> control cabinet (e.g.
Eco
AUC
Bell)
<2Ω
●
Control cabinet <> Central grounding point
<2Ω
●
Atomizer (without medium)
Limit value
Measured value
Paint pipe / nozzle <> Central grounding point
<10Ω
●
Comment: Before checking the speed, the distance between the control air ring and the bell
disk is to be checked.
The distance between the outer edge of the bell disk
and control air ring (1) must be checked with the test
tool W02020284. The information about the surface to
be used for a certain sprayer gun type is engraved on
the testing tool.
Checked:
2 High Voltage EcoHT G500 external charging
ATEX category 2G/3G
Insulation measurement with test voltage
1000V
Limit value
Measured value
Pickup point work piece <> Central grounding
point
<1MΩ
MΩ
Insulation measurement with test voltage 50V
Limit value
Measured value
Shaft/turbine (with motor bearing air) <> Central
grounding point
<10
0kΩ
kΩ
Set point, actual value comparison
Control display
Controller
Electrode atomizer
Nominal value
Actual value
Actual value
Actual value
U [kV]
I [µA]
U [V]
I [V]
U [kV]
200µA
kV
µA
V
V
kV
300µA
kV
µA
V
V
kV
400µA or max. I
kV
µA
V
V
kV